Fuser Assembly Temperature Control
Temperature change
Figure 2
Temperature control
During a warm-up cycle, the fuser temperature is increased to a predetermined level.
The warm-up control is performed when the power is turned ON, the front door is opened and
closed, and the pause mode is cancelled.
During the standby state, the fuser temperature is kept lower (130°C) than during printing so
as to economize on power consumption.
Table 1: Thermistor-Detected Temperature at Start of Temperature Control
Less than 50°C
(122°F)
50°C to 130°C
(122°F to 266°F)
More than 130°C (266°F)
Mode before
Tempera-
ture Control
Power OFF Mode 1 Mode 2 Mode 3
Mode 1 Mode 1
Mode 2 Mode 2 Mode 3
Mode 3