REP 11 Paper Empty Sensor
Parts list on PL 12
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer supply
while performing tasks that do not need electricity. Electricity can cause death or injury. Moving
parts can cause injury.
1. Remove the imaging cartridge (REP 4 steps 1 and 2).
2. Use a flat bladed screwdriver to carefully release the right side of the front door, then remove
the front door.
3. Remove the left cover (REP 24) and the right cover (REP 25).
4. Remove the CPU metal cage (REP 18, steps 3 to 5).
5. Disconnect PJ12 and PJ14 from the Main PBA.
6. Unhook two tabs, disconnect one connector. Remove the paper feed upper guide assembly.
Figure 1
7. Unhook two tabs and remove the tray.
Figure 2