Status Indicator RAPs
2-12 11/06 FaxCentre 2121/2121L
10 Abnormally High Fuser Temperature RAP
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer supply
while performing tasks that do not need electricity. Electricity can cause death or injury. Moving
parts can cause injury.
Description
• The temperature detected by the thermistor remains higher than 235°C/455°F for a predeter-
mined period of time.
Table 9: Abnormally High Fuser Temperature
Checks and Causes Solutions
1. Check the thermistor. 1. Install a new fuser (PL 10).
2. Install a new Main PBA (PL 5).
3. Install a new LVPS (PL 11).
2. Check the thermostat.
3. Check the fuser.