33
1. Jog run (F1-00)
Make sure that the motor shaft is not connected to the machine before jogging!
When the servo is in jog run mode, gain and other parameters will join the process. Please
adjust the parameters according to the jog run status.
P3-18
JOG speed
Unit
Default
Setting
range
Suitable
mode
Change
Effective
1Rpm
100
0~1000
JOG
Servo OFF
Immediately
2. Test run (F1-01)
Make sure that the motor shaft is not connected to the machine before test run!
When servo drive is connected with non-original encoder line or power line, test run must be
run first to ensure that the encoder line or power line is connected correctly.
Test run can detect the connection of power line and encoder feedback. Please operate the
servo as the following steps. If the motor shaft jitter or servo alarm, please cut off the power at
once then check the wiring.
F1-00
Press ENTER
INC
Keep Press ENTER
Reverse
Forward
DEC

Table of Contents