Protection and features
Electronic thermal motor protection against overload.
Temperature monitoring of the heatsink ensures that the adjustable frequency drive
trips if the temperature reaches 203°F ±10°F (95°C ±5° C). An overload temperature
cannot be reset until the temperature of the heatsink is below 158°F ±9°F (70°C ±5°C)
(Guideline — these temperatures may vary for different power sizes, frame sizes,
enclosure, etc.)
The adjustable frequency drive is protected against short-circuits on motor terminals
U, V, W.
If a line phase is missing, the adjustable frequency drive trips a warning (depending on
the load).
Monitoring of the intermediate circuit voltage ensures that the adjustable frequency
drive trips if the intermediate circuit voltage is too low or too high.
The adjustable frequency drive is protected against ground faults on moto terminals U,
V, W.
9.3 Fuse tables
Non-UL compliance
If UL/cUL is not to be complied with, we recommend using the following fuses, which will
ensure compliance with EN50178:
Table 42: Non-UL compliance, line fuses, 380–480 V
1500–3500 380–480 V type gG
4000–6000 380–480 V type gR
UL compliance
The fuses below are suitable for use on a circuit capable of delivering 100,000 Arms
(symmetrical), 240 V, 480 V, 500 V, or 600 V depending on the drive voltage rating. With
the proper fusing, the drive Short Circuit Current Rating (SCCR) is 100,000 Arms.
Table 43: Frame size D, line fuses, 380–480 V
Size/Type
Fuse options
Bussmann
PN
Littelfuse
PN
Littelfuse
PN
Bussmann
PN
SIBA
PN
Ferraz-
Shawmut
PN
Ferraz-
Shawmut
PN
(Europe)
Ferraz-
Shawmut
PN
(North
America)
1500 170M2619 LA50QS300-4 L50S-300 FWH-300A 20 610
31.315
A50QS300-4 6,9URD31D08
A0315
A070URD31KI
0315
2000 170M2620 LA50QS350-4 L50S-350 FWH-350A 20 610
31.350
A50QS350-4 6,9URD31D08
A0350
A070URD31KI
0350
2500 170M2621 LA50QS400-4 L50S-400 FWH-400A 20 610
31.400
A50QS400-4 6,9URD31D08
A0400
A070URD31KI
0400
3000 170M4015 LA50QS500-4 L50S-500 FWH-500A 20 610
31.550
A50QS500-4 6,9URD31D08
A0550
A070URD31KI
0550
3500 170M4016 LA50QS600-4 L50S-600 FWH-600A 20 610
31.630
A50QS600-4 6,9URD31D08
A0630
A070URD31KI
0630
4500 170M4017 LA50QS800-4 L50S-800 FWH-800A 20 610
31.800
A50QS800-4 6,9URD31D08
A0800
A070URD31KI
0800
9 Technical Specification
Aquavar
®
Intelligent Pump Controller - 150 HP to 600 HP INSTRUCTION MANUAL 159

Table of Contents