11-5 Communication Command Description
COMMUNICATION WITH PC
11-5-3
Utilities
(1-1) @INIT PGM
Initializes all program data.
Transmission example : @INIT PGM c/r l/f
Response example : OK c/r l/f
(1-2) @INIT PNT
Initializes all point data.
Transmission example : @INIT PNT c/r l/f
Response example : OK c/r l/f
(1-3) @INIT PRM <robot number>
Initializes the parameter data to match the specified robot.
For robot numbers, refer to "15-1-2 Robot number list".
Transmission example : @INIT PRM 516 c/r l/f ................ Parameter data is initialized to
match the model MR16T
robot.
Response example : OK c/r l/f
(1-4) @INIT CLOCK
Initializes the timer to 0, which is used to measure the total operation time of the SRCP controller.
The alarm history and error history are also initialized at this point.
Transmission example : @INIT CLOCK c/r l/f
Response example : OK c/r l/f
(1-5) @INIT ALM
Initializes the alarm history.
Transmission example : @INIT ALM c/r l/f
Response example : OK c/r l/f
(1-6) @INIT ERR
Initializes the error history.
Transmission example : @INIT ERR c/r l/f
Response example : OK c/r l/f