8 - 17
– +
ELEC
EAS00756
STARTING CIRCUIT CUT-OFF SYSTEM
OPERATION (XP500)
If the engine stop switch is set to “” and the
main switch is set to “ON” (both switches are
closed), the starter motor can only operate if
the following conditions are met:
• A brake lever is pulled to the handlebar (the
brake light switch is closed) and the side-
stand is up (the sidestand switch is closed).
1
Battery
2
Main fuse
3
Main switch
4
Ignition fuse
5
Engine stop switch
6
Starting circuit cut-off relay 1
7
Sidestand switch
8
Signaling system fuse
9
Front brake light switch
0
Rear brake light switch
A
Start switch
B
Starter relay
C
Starter motor
ELECTRIC STARTING SYSTEM