Drive
Model
Terminal
For Japan and Asia
<1>
For United States
<2>
For Europe and China
<3>
Screw
Size
Tightenin
g
Torque
N•m
(lb.in.)
Recomm.
Gauge
mm
2
Wire Range
mm
2
Recomm.
Gauge
AWG,
kcmil
Wire Range
AWG, kcmil
Recomm.
Gauge
mm
2
Wire Range
mm
2
4A0011
R/L1, S/L2,
T/L3
2 2 to 5.5 12 14 to 10 2.5 2.5 to 6
M4
1.2 to 1.5
(10.6 to
13.3)
U/T1, V/T2,
W/T3
2 2 to 5.5 14 14 to 10 2.5 2.5 to 6
⊖, ⊕1, ⊕2
2 2 to 5.5 – 14 to 10 – 2.5 to 6
B1, B2 2 2 to 5.5 – 14 to 10 – 2.5 to 6
2 2 to 5.5 10 14 to 10 2.5 2.5 to 6
<1> Gauges listed here are for use in Japan and Asia.
<2> Gauges listed here are for use in the United States.
<3> Gauges listed here are for use in Europe and China.
Note: Use crimp insulated terminals or insulated tubing for wiring these connections. Wires should have a
continuous maximum allowable temperature of 75 °C 600 V UL approved vinyl sheathed insulation.
Ambient temperature should not exceed 30 °C.
Closed-Loop Crimp Terminal Recommendations
Yaskawa recommends crimp terminals made by JST and Tokyo DIP for the insulation cap.
Table C.10 matches drives models with crimp terminals and insulation caps. Orders can be
placed with a Yaskawa representative or directly with the Yaskawa sales department.
Table C.10 Closed-Loop Crimp Terminal Size
Drive
Model
Wire Gauge AWG
Terminal
Screws
Crimp
Terminal
Model No.
Tool
Insulation
Cap Model
No.
Code
<2>
R/L1, S/L2,
T/L3
U/T1, V/T2,
W/T3
Machine
No.
Die Jaw
200 V Class Single-Phase Drives
BA0001
BA0002
BA0003
18
M3.5
R1.25-3.5
YA-4 AD-900 TP-003
100-066-217
16
14
<1>
R2-3.5 100-066-218
BA0006
14
<1>
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12
R5.5-4 TP-005 100-054-029
10
C.3 UL Standards
268