Table 4.9 Derated Torque Characteristics, Examples E to H
Example E 50 Hz Example F 50 Hz Example G 60 Hz Example H 60 Hz
0
8
200
1.3 25 50
35
Voltage (V)
Frequency (Hz)
0
9
200
1.3 25 50
50
Voltage (V)
Frequency (Hz)
0
8
200
1.5 30 60
35
Voltage (V)
Frequency (Hz)
0
9
200
1.5 30 60
50
Voltage (V)
Frequency (Hz)
Table 4.10 High Starting Torque, Examples I to L
Example I 50 Hz Example J 50 Hz Example K 60 Hz Example L 60 Hz
0
12
200
1.3 2.5 50
19
Voltage (V)
Frequency (Hz)
0
13
200
1.3 2.5 50
24
Voltage (V)
Frequency (Hz)
0
12
200
1.5 3 60
19
Voltage (V)
Frequency (Hz)
0
15
200
1.5 3 60
24
Voltage (V)
Frequency (Hz)
Table 4.11 Rated Output Operation, Examples M to O
Example M 90 Hz Example N 120 Hz Example O 180 Hz
0
12
16
200
1.5 3 9060
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 12060
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 18060
Voltage (V)
Frequency (Hz)
n
V/f Pattern Settings E1-04 to E1-10
Set up the V/f pattern as shown in Figure 4.16.
No. Parameter Name Setting Range Default
E1-04 Maximum Output Frequency 40.0 to 400.0 Hz 60 Hz
E1-05 Maximum Voltage
0.0 to 255.0 V
<1>
230 V
E1-06 Base Frequency 0.0 to 400.0 Hz 60 Hz
4.5 Basic Operation
YASKAWA ELECTRIC TOEP C710606 26B YASKAWA AC Drive – J1000 Quick Start Guide
103
4
Start-Up Programming
& Operation
http://nicontrols.com

Table of Contents

Related product manuals