u
d: References
Reference parameters
are used to set the various frequency reference values during operation.
No. Name Description Range Def. Mode
Addr.
Hex
Pg.
d1: Frequency Reference
Use d1 parameters to configure the drive frequency reference.
d1-01
<1>
Frequency
Reference 1
Frequency reference. Refer
to
Frequency Reference
Source: b1-01 on page 88 for instructions to use
d1-01 as the main frequency reference.
0.00 to
400.00
Hz
<2>
0.00
Hz
S 280 97
d1-02
<1>
Frequency
Reference 2
Frequency reference when digital input "Multi-Step
Speed Reference 1" (H1-oo = 3) is on.
0.00
Hz
S 281 97
d1-03
<1>
Frequency
Reference 3
Frequency reference when digital input "Multi-Step
Speed Reference 2” (H1-oo = 4) is on.
0.00
Hz
S 282 97
d1-04
<1>
Frequency
Reference 4
Frequency reference when digital inputs "Multi-Step
Speed Reference 1, 2" (H1-oo = 3 and 4) are on.
0.00
Hz
S 283 97
d1-05
<1>
Frequency
Reference 5
Frequency reference when digital input "Multi-Step
Speed Reference 3" (H1-oo = 5) is on.
0.00
Hz
O 284 –
d1-06
<1>
Frequency
Reference 6
Frequency reference when digital inputs "Multi-Step
Speed Reference 1, 3 " (H1-oo = 3 and 5) are on.
0.00
Hz
O 285 –
d1-07
<1>
Frequency
Reference 7
Frequency reference when digital inputs "Multi-Step
Speed Reference 2, 3" (H1-oo = 4 and 5) are on.
0.00
Hz
O 286 –
d1-08
<1>
Frequency
Reference 8
Frequency reference when multi-function input
"Multi-Step
speed
reference 1, 2, 3" (H1-oo = 3, 4,
5) are on.
0.00
Hz
O 287 –
d1-17
<1>
Jog Frequency
Reference
Frequency reference when digital inputs "Jog
Frequency Reference", "Forward Jog" or "Reverse
Jog." are on.
6.00
Hz
S 292 –
d2: Frequency Upper and Lower Limits
Use d2 parameters to configure the frequency reference limits.
d2-01
Frequency
Reference
Upper Limit
Sets the frequency reference upper limit as a
percentage of maximum output frequency (E1-04).
Output speed is limited to this value even if the
frequency reference
is higher. This limit applies to all
frequency reference sources.
0.0 to
110.0
100.
0%
O 289 –
d2-02
Frequency
Reference
Lower Limit
Sets the frequency reference lower limit as a
percentage of maximum output frequency (E1-04).
Output speed is limited to this value even if the
frequency reference is lower. This limit applies to all
frequency reference sources.
0.0 to
110.0
0.0% O 28A –
d3: Jump Frequency
Use d3 parameters to configure the drive Jump Frequency settings.
B.2 Parameter Table
216
YASKAWA ELECTRIC TOEP C710606 26B YASKAWA AC Drive – J1000 Quick Start Guide