Parameter Details
2
2.7 F: Options
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING 285
■ F7-71: PZD2 Read (Output Frequency)
No.
(Hex.)
Name Description
Default
(Range)
F7-71
(078B)
PZD2 Read (Output
Frequency)
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD2 (PPO input). PZD2
(PPO input) functions as the HIW when F7-71 = 0.
0
■ F7-72: PZD3 Read
No.
(Hex.)
Name Description
Default
(Range)
F7-72
(078C)
PZD3 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO input). A
value of 0 will disable the PZD3 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■ F7-73: PZD4 Read
No.
(Hex.)
Name Description
Default
(Range)
F7-73
(078D)
PZD4 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO input). A
value of 0 will disable the PZD4 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■ F7-74: PZD5 Read
No.
(Hex.)
Name Description
Default
(Range)
F7-74
(078E)
PZD5 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO input). A
value of 0 will disable the PZD5 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■ F7-75: PZD6 Read
No.
(Hex.)
Name Description
Default
(Range)
F7-75
(078F)
PZD6 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD6 (PPO input). A
value of 0 will disable the PZD6 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■ F7-76: PZD7 Read
No.
(Hex.)
Name Description
Default
(Range)
F7-76
(0790)
PZD7 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD7 (PPO input). A
value of 0 will disable the PZD7 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■ F7-77: PZD8 Read
No.
(Hex.)
Name Description
Default
(Range)
F7-77
(0791)
PZD8 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD8 (PPO input). A
value of 0 will disable the PZD8 (PPO input) load operation from the MEMOBUS/Modbus register.
0
■ F7-78: PZD9 Read
No.
(Hex.)
Name Description
Default
(Range)
F7-78
(0792)
PZD9 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD9 (PPO input). A
value of 0 will disable the PZD9 (PPO input) load operation from the MEMOBUS/Modbus register.
0