EasyManua.ls Logo

YASKAWA GA500 GA50U Series

YASKAWA GA500 GA50U Series
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter List
1
1.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING 137
No.
*1
Name Unit Default
- Drive Model - 2042 2056 2070 2082
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 6B 6D 6E 6F
E2-11
(E4-11, E5-
02)
Motor Rated
Power
kW 7.5 11 11 15 15 18.5 18.5 22
L3-24
Motor Accel
Time @ Rated
Torque
s 0.175 0.265 0.265 0.244 0.244 0.317 0.317 0.355
L8-02
Overheat
Alarm Level
°C 115 115 125 125 120 120 135 135
L8-09
Output Ground
Fault
Detection
- 1 1 1 1 1 1 1 1
n1-03
Hunting
Prevention
Time Constant
ms 10 10 10 10 10 10 10 10
n3-02
HSB Current
Limit Level
1 150 120 150 120 150 120 150 120
n5-02
Motor Inertia
Acceleration
Time
s 0.175 0.265 0.265 0.244 0.244 0.317 0.317 0.355
*1 Parameters within parentheses are for motor 2.
Three-Phase 400 V Class
No.
*1
Name Unit Default
- Drive Model - 4001 4002 4004 4005
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 91 92 93 94
E2-11
(E4-11, E5-
02)
Motor Rated
Power
kW 0.2 0.4 0.4 0.75 0.75 1.5 1.5 2.2
b3-04
V/f Gain
during Speed
Search
% 100 100 100 100 100 100 100 100
b3-06
Speed
Estimation
Current Level
1
- 1.0 1.0 0.5 0.5 0.5 0.5 0.5 0.5
b3-08
Speed
Estimation
ACR P Gain
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-26
Direction
Determination
Level
- 1000 1000 1000 1000 1000 1000 1000 1000
b8-03
Energy Saving
Filter Time
s 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b8-04
Energy Saving
Coefficient
Value
- 713.8 576.4 576.4 447.4 447.4 338.8 338.8 313.6
C6-02
Carrier
Frequency
Selection
- 3 7 3 7 3 7 3 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 0.6 1 1 1.6 1.6 3.1 3.1 4.2

Table of Contents

Related product manuals