1.21 Defaults by Drive Model and Duty Rating ND/HD
136 YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING
No.
*1
Name Unit Default
- Drive Model - 2042 2056 2070 2082
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 6B 6D 6E 6F
E2-11
(E4-11, E5-
02)
Motor Rated
Power
kW 7.5 11 11 15 15 18.5 18.5 22
b3-04
V/f Gain
during Speed
Search
% 100 100 100 100 100 100 100 100
b3-06
Speed
Estimation
Current Level
1
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-08
Speed
Estimation
ACR P Gain
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-26
Direction
Determination
Level
- 1000 1000 1000 1000 1000 1000 1000 1000
b8-03
Energy Saving
Filter Time
s 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b8-04
Energy Saving
Coefficient
Value
- 72.69 70.44 70.44 63.13 63.13 57.87 57.87 51.79
C6-02
Carrier
Frequency
Selection
- 3 7 3 7 3 7 3 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 26.6 39.7 39.7 53 53 65.8 65.8 77.2
E2-02
(E4-02)
Motor Rated
Slip
Hz 1.3 1.7 1.7 1.6 1.6 1.67 1.67 1.7
E2-03
(E4-03)
Motor No-
Load Current
A 8 11.2 11.2 15.2 15.2 15.7 15.7 18.5
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω 0.288 0.23 0.23 0.138 0.138 0.101 0.101 0.079
E2-06
(E4-06)
Motor
Leakage
Inductance
% 15.5 19.5 19.5 17.2 17.2 15.7 20.1 19.5
E2-10
(E4-10)
Motor Iron
Loss
W 262 245 245 272 272 505 505 538
E5-01
PM Motor
Code Selection
- FFFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF
L2-02
Power Loss
Ride Through
Time
s 1 1 2 2 2 2 2 2
L2-03
Minimum
Baseblock
Time
s 0.8 0.9 0.9 1 1 1 1 1
L2-04
Powerloss V/f
Recovery
Ramp Time
s 0.3 0.3 0.3 0.6 0.6 0.6 0.6 0.6
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 190 190 190 190 190 190 190 190
L3-02
Stall Prevent
Level during
Accel
% 150 120 150 120 150 120 150 120
L3-06
Stall Prevent
Level during
Run
% 150 120 150 120 150 120 150 120