1
1.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING 133
Three-Phase 200 V Class
No.
*1
Name Unit Default
- Drive Model - 2001 2002 2004 2006
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 60 61 62 63
E2-11
(E4-11, E5-
02)
Motor Rated
Power
kW 0.1 0.2 0.2 0.4 0.4 0.75 0.75 1.1
b3-04
V/f Gain
during Speed
Search
% 100 100 100 100 100 100 100 100
b3-06
Speed
Estimation
Current Level
1
- 1 1 1 1 1 1 0.5 0.5
b3-08
Speed
Estimation
ACR P Gain
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-26
Direction
Determination
Level
- 1000 1000 1000 1000 1000 1000 1000 1000
b8-03
Energy Saving
Filter Time
s 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b8-04
Energy Saving
Coefficient
Value
- 481.7 356.9 356.9 288.2 288.2 223.7 223.7 196.6
C6-02
Carrier
Frequency
Selection
- 4 7 4 7 4 7 4 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 0.6 1.1 1.1 1.9 1.9 3.3 3.3 4.9
E2-02
(E4-02)
Motor Rated
Slip
Hz 2.5 2.6 2.6 2.9 2.9 2.5 2.5 2.6
E2-03
(E4-03)
Motor No-
Load Current
A 0.4 0.8 0.8 1.2 1.2 1.8 1.8 2.3
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω 35.98 20.56 20.56 9.842 9.842 5.156 5.156 3.577
E2-06
(E4-06)
Motor
Leakage
Inductance
% 21.6 20.1 20.1 18.2 18.2 13.8 13.8 18.5
E2-10
(E4-10)
Motor Iron
Loss
W 6 11 11 14 14 26 26 38
E5-01
PM Motor
Code Selection
- FFFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF
L2-02
Power Loss
Ride Through
Time
s 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2
L2-03
Minimum
Baseblock
Time
s 0.2 0.3 0.2 0.3 0.2 0.3 0.3 0.4
L2-04
Powerloss V/f
Recovery
Ramp Time
s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 190 190 190 190 190 190 190 190
L3-02
Stall Prevent
Level during
Accel
% 150 120 150 120 150 120 150 120

Table of Contents