EasyManua.ls Logo

YASKAWA GA500 GA50U Series

YASKAWA GA500 GA50U Series
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.8 H: Terminal Function Selection
356 YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING
H7-41: Virtual Analog Output Function
No.
(Hex.)
Name Description
Default
(Range)
H7-41
(1164)
Virtual Analog Output
Function
Sets the monitor to be output from the virtual analog output.
102
(0 - 999)
Set the x-xx part of the Ux-xx [Monitor]. For example, set H7-41 = 102 to monitor U1-02 [Output Frequency].
H7-42: Virtual Analog Output FilterTime
No.
(Hex.)
Name Description
Default
(Range)
H7-42
(1165)
Virtual Analog Output
FilterTime
Sets the time constant for a primary filter of the virtual analog output.
0.00 s
(0.00 - 2.00 s)
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV