2.11 o: Keypad-Related Settings
432 YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING
o1-39: Show Initial Setup Screen
No.
(Hex.)
Name Description
Default
(Range)
o1-39
(11BC)
RUN
Show Initial Setup Screen
Sets the function to show the LCD keypad initial setup screen each time you energize the drive. This
parameter is only available with an LCD keypad.
1
(0, 1)
The initial setup screen shows a menu where you can select the display language, set the date, time, and other basic
settings. When you set this parameter to 0, the drive will not show this screen each time you energize the drive.
0 : No
The drive will not show the initial setup display screen each time you energize the drive. The drive will show the
Home screen.
1 : Yes
When you input the Run command before you energize the drive or when the you turn on the Run command while the
drive shows the initial setup screen, the drive will replace the initial setup screen with the Home screen.
o1-40: Home Screen Display Selection
No.
(Hex.)
Name Description
Default
(Range)
o1-40
(11BD)
RUN
Home Screen Display
Selection
Sets the monitor display mode for the Home screen. This parameter is only available with an LCD
keypad.
0
(0 - 3)
0 : Custom Monitor
1 : Bar Graph
2 : Analog Gauge
3 : Trend Plot
o1-41: 1st Monitor Area Selection
No.
(Hex.)
Name Description
Default
(Range)
o1-41
(11C1)
RUN
1st Monitor Area Selection
Sets the horizontal axis value used to display the monitor set in o1-24 [Custom Monitor 1] as a bar
graph. This parameter is only available with an LCD keypad.
0
(0 - 1)
0 : +/- Area ( - o1-42 o1-42 )
1 : + Area ( 0 o1-42 )
o1-42: 1st Monitor Area Setting
No.
(Hex.)
Name Description
Default
(Range)
o1-42
(11C2)
RUN
1st Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in o1-24 [Custom Monitor 1] as a bar
graph. This parameter is only available with an LCD keypad.
100.0%
(0.0 - 100.0%)
o1-43: 2nd Monitor Area Selection
No.
(Hex.)
Name Description
Default
(Range)
o1-43
(11C3)
RUN
2nd Monitor Area Selection
Selects the horizontal range used to display the monitor set in o1-25 [Custom Monitor 2] as a bar
graph. This parameter is only available with an LCD keypad.
0
(0 - 1)
0 : +/- Area ( - o1-44 o1-44 )
1 : + Area ( 0 ~ o1-44 )
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV