Parameter Details
2
2.12 T: Auto-Tuning
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING 451
■ T1-06: Number of Motor Poles
No.
(Hex.)
Name Description
Default
(Range)
T1-06
(0706)
Number of Motor Poles
Sets the number of motor poles.
4
(2 to 120)
■ T1-07: Motor Base Speed
No.
(Hex.)
Name Description
Default
(Range)
T1-07
(0707)
Motor Base Speed
Sets the motor base speed for Auto-Tuning (min
-1
(r/min)).
1750 min
-1
(r/min)
(0 - 35400 min
-1
(r/min))
■ T1-09: Motor No-Load Current
No.
(Hex.)
Name Description
Default
(Range)
T1-09
(0709)
Motor No-Load Current
Sets the no-load current of the motor.
-
(0A - T1-04; max. of 2999.9)
Note:
The display units are different for different models:
• 0.01 A: B001 - B018, 2001 - 2042, 4001 - 4023
• 0.1 A: 2056 - 2082, 4031 - 4060
The value shown is the no-load current that the drive automatically calculates from the values set in T1-02 [Motor
Rated Power] and T1-04 [Motor Rated Current]. Set the no-load current shown on the motor test report. If the motor
test report is not available, do not change this parameter.
■ T1-10: Motor Rated Slip Frequency
No.
(Hex.)
Name Description
Default
(Range)
T1-10
(070A)
Motor Rated Slip Frequency
Sets motor rated slip.
-
(0.000 - 20.000 Hz)
Shows 0.000 Hz as the default value. Set the rated slip shown on the motor test report. If the motor test report is not
available, do not change this parameter.
■ T1-11: Motor Iron Loss
No.
(Hex.)
Name Description
Default
(Range)
T1-11
(070B)
Motor Iron Loss
Sets the iron loss to calculate the energy-saving coefficient.
Determined by E2-10 or E4-
10
(0 - 65535 W)
Note:
The default setting is different for different motor codes and motor parameter settings.
The value shown is E2-10 [Motor Iron Loss] or E4-10 [Motor 2 Iron Loss] for the motor output set in T1-02 [Motor
Rated Power]. If the motor test report is available, enter the motor iron loss value to T1-11.
■ T1-12: Test Mode Selection
No.
(Hex.)
Name Description
Default
(Range)
T1-12
(0BDB)
Test Mode Selection
Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can operate the motor
with a light load attached after Stationary Auto-Tuning is complete, enable this parameter.
0
(0, 1)
0 : No
1 : Yes