EasyManua.ls Logo

YASKAWA HV600 Series - Rated Output Current

YASKAWA HV600 Series
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Receiving
YASKAWA TOEPC71061732E HV600 Drive Installation & Primary Operation 11
No. Description
5 EMC filter
C: Built-in EMC filter for C2
6 Protection design
B: IP20/UL Open Type
F: IP20/UL Type 1
V: IP55/UL Type 12
7 Environmental specification
A: Standard
Rated Output Current
Table 4.2 and Table 4.3 give the rated output current values.
Note:
These output current values are applicable for drives that operate at standard specifications.
Derate the current in applications that:
Increase the carrier frequency
Have high ambient temperature
Use side-by-side installation.
Table 4.2 Output Current for Three-Phase AC 208 V Class Models (NEMA Rating)
Model
Maximum Applicable Motor Output
kW (HP)
Rated Output Current
A
2011
2.2 (3) 10.6
2017
3.7 (5) 16.7
2024
5.5 (7.5) 24.2
2031
7.5 (10) 30.8
2046
11 (15) 46.2
2059
15 (20) 59.4
2075
18.5 (25) 74.8
2088
22 (30) 88
2114
30 (40) 114
2143
37 (50) 143
2169
45 (60) 169
2211
55 (75) 211
2273
75 (100) 273
Table 4.3 Output Current for Three-Phase AC 480 V Class Models (NEMA Rating)
Model
Maximum Applicable Motor Output
kW (HP)
Rated Output Current
A
4005 2.2 (3) 4.8
4008 3.7 (5) 7.6
4011 5.6 (7.5) 11
4014 7.5 (10) 14
4021 11.2 (15) 21
4027 15 (20) 27
4034 18.6 (25) 34
4040 22 (30) 40
4052 30 (40) 52
4065 37 (50) 65
4077 45 (60) 77

Table of Contents