EasyManua.ls Logo

YASKAWA HV600 Series - Wiring the Main Circuit Terminal Block Using Procedure C

YASKAWA HV600 Series
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Electrical Installation
YASKAWA TOEPC71061732E HV600 Drive Installation & Primary Operation 41
9. Tighten the bolts to the specified torque.
Figure 7.13 Tighten the Terminal Block Bolts
10. Put the terminal cover back in its initial position.
Wiring the Main Circuit Terminal Block Using Procedure C
Main Circuit Terminal Block Wiring Procedure
1. Remove the terminal cover.
2. Remove the screws that attach the conduit bracket and remove the conduit bracket from the drive.
A - Conduit bracket
Figure 7.14 Remove the Conduit Bracket
3. Put the end of a straight-edge screwdriver into the center hole and move it up and down to remove the knock-
out hole.
WARNING
Injury to Personnel. Carefully move the screwdriver to remove the knock-out holes. If you use too much
pressure on the circular metal plates, they can eject and cause injury.

Table of Contents

Related product manuals