12 UL Standards
76 YASKAWA TOEPC71061732E HV600 Drive Installation & Primary Operation
■ 208 V Class Branch Circuit Protection
Table 12.2 Factory-Recommended Branch Circuit Protection: 208 V Class
Drive Model
Semiconductor Protection Fuse
Model
Manufacturer: EATON/Bussmann
Maximum Applicable Motor Output
kW (HP)
Class J or T Time Delay Fuse
Rated Current
A
2011 FWH-40B 2.2 (3) 17.5
2017 FWH-45B 3.7 (5) 25
2024 FWH-80B 5.5 (7.5) 40
2031 FWH-125B 7.5 (10) 50
2046 FWH-125B 11 (15) 80
2059 FWH-175B 15 (20) 100
2075 FWH-200B 18.5 (25) 125
2088 FWH-225A 22 (30) 150
2114 FWH-225A 30 (40) 175
2143 FWH-250A 37 (50) 250
2169 FWH-275A 45 (60) 300
2211 FWH-600A 55 (75) 350
2273 FWH-800A 75 (100) 450
■ 480 V Class Branch Circuit Protection
Table 12.3 Factory-Recommended Branch Circuit Protection: 480 V Class
Drive Model
Semiconductor Protection Fuse
Model
Manufacturer: EATON/Bussmann
Maximum Applicable Motor Output
kW (HP)
Class J or T Time Delay Fuse
Rated Current
A
4005 FWH-25A14F 2.2 (3) 8
4008 FWH-30A14F 3.7 (5) 12
4011 FWH-40B 5.6 (7.5) 17.5
4014 FWH-45B 7.5 (10) 20
4021 FWH-60B 11.2 (15) 35
4027 FWH-80B 14.9 (20) 45
4034 FWH-100B 18.6 (25) 50
4040 FWH-125B 22 (30) 70
4052 FWH-150B 30 (40) 90
4065 FWH-200B 37 (50) 110
4077 FWH-225A 45 (60) 125
4096 FWH-225A 56 (75) 150
4124 FWH-225A 75 (100) 200
4156 FWH-325A 93 (125) 250
4180 FWH-500A 112 (150) 300
4240 FWH-600A 149 (200) 400
4302 FWH-700A 186 (250)
500
◆ Low Voltage Wiring for Control Circuit Terminals
You must provide low voltage wiring as specified by the National Electric Code (NEC), the Canadian Electric Code,
Part I (CEC), and local codes. Yaskawa recommends the NEC class 1 circuit conductor. Use the UL Listed class 2
power supply for external power supply.