5 Common Drive Specifications
14 YASKAWA TOEPC71061732E HV600 Drive Installation & Primary Operation
Table 5.4 Certifications and Standard Compliance
Item Specification
c-UL-us
UL 508C
CE Low Voltage
Directive
2014/35/EU
• EN 61800-5-1:2007
• IEC 61800-5-1:2007
CE EMC Directive
2014/30/EU
EN 61800-3:2004/A1:2012
First environment restricted distribution
CE Machinery
Directive
2006/42/EC
• EN 61800-5-2:2007 (SIL3)
• IEC 61800-5-2:2007 (SIL3)
• EN 62061:2005/A2:2015 (SIL CL3)
• IEC62061:2005+AMD1:2012+AMD2:2015 CSV (SIL CL3)
• EN ISO 13849-1:2015 (PL e (Cat.Ⅲ))
TUV SUD
• Functional Safety
– IEC 61800-5-2:2016 (SIL3)
– EN 61800-5-2:2017 (SIL3)
– EN 61508:2010 (SIL3)
– IEC 61508:2010 (SIL3)
– EN 62061:2005/A1:2013 (SIL CL3)
– IEC 62061:2005+AMD1:2012+AMD2:2015 CSV (SIL CL3)
• Machinery Safety
– EN ISO 13849-1:2015 (Cat.Ⅲ, PL e)
– ISO 13849-1:2015 (Cat.Ⅲ, PL e)
• EMC
– EN 61000-6-7:2015
– EN 61326-3-1:2008
– EN 61326-3-1:2017
– EN 61800-3:2004+A1:2012
– EN 61800-5-2:2017
• LVD
– EN 61800-5-1:2007
– IEC 61800-5-1:2007
RoHS Directive
2011/65/EU
-
WEEE Directive
2012/19/EU
-
Table 5.5 Enclosure Ratings
Item Specification
Protection Design
IP20/UL Open Type
IP20/UL Type 1
IP55/UL Type 12
Note:
Install a UL Type 1 kit on an IP20/UL Open Type drive to convert the drive to an IP20/UL Type 1.
◆ Area of Use
Install this product in a location with Overvoltage Category III and pollution degree 2 or less.
■ Ambient Temperature Setting
Maintain the ambient temperature within the following ranges according to the enclosure type.
• IP20/UL Type 1 and IP55/UL Type 12: -10 °C to +40 °C (14 °F to 104 °F)
• IP20/UL Open Type: -10 °C to +50 °C (14 °F to 122 °F)