EasyManua.ls Logo

YASKAWA Sigma Mini SGMM Series - Page 133

YASKAWA Sigma Mini SGMM Series
283 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USING THE DIGITAL OPERATOR
3.1.5 Operation in Parameter Setting Modecont.
3-8
Changing the Memory Switch Settings (Cn-01, Cn-02)
The bits of the memory switches can be turned ON and OFF to select the functions required.
The following example shows how to turn ON bit 4 of memory switch Cn-02.
1) Press
DSPL
SET
to select the parameter set-
ting mode.
2) Select the parameter number to set.
Press the
and keys to select the
digit.
Press the
and keys to change the
value.
3) Press
DATA
ENTER
to display the current data for
the memory switch selected at step 2.
4) Press the
and keys to select the
bit number to set.
5) Press the
and keys to set the
memory switch data ON or OFF for the bit
number.
6) Repeat steps 4 and 5 as often as required.
7) Press
DATA
ENTER
to store the data.
8) Press
DATA
ENTER
once more to display the pa-
rameter number again.
TERMS
Turning bits ON and OFF
Memory switches use bits, not numbers, to select
functions.
Sixteen bits are available (0 to 9 and A to F). Select
the required functions by turning the appropriate bit
ON (function ON) or OFF (function OFF).
: = OFF
=ON
3
Setting
Mode
The selected
digit flashes.
Parameter
Number
Memory
Switch Data
Bit Numbe
r
to Set
Bit Number to Set
Bit
Number
Press either key.
or
The stored data
flashes.
Parameter
Number
Memory Switch
Data
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Related product manuals