APPLICATIONS
2.6.5 Setting Speed Bias
2-52
Cn-01
Setting
Control Mode
Bit B Bit A
Control
Mode
Speed Control
This is normal speed control.
D Speed reference is input from V-REF.
D Signal /P-CON is used to switch between
P control and PI control.
Servopack
Speed
reference
P/PI
(CN1-12)
0 0
/P-CON is open
(OFF)
PI control
P/PI
changeover
(CN1 12)
(CN1-*1)
/P-CON
/P-CON is closed
(ON)
P control
(CN1- 1)
D Torque reference input T-REF cannot be
used.
Using Proportional Control
Proportional control can be used in the following two ways.
When operation is performed by sending speed references from the host controller to the
Servopack, the host controller can selectively use P control mode for particular conditions
only. This method can prevent the occurrence of overshoot and also shorten settling time.
For particular conditions, refer to 2.6.6 Mode Switch.
If PI control mode is used when the speed reference has a reference offset, the motor may
rotate at a very slow speed and fail to stop even if 0 is specified as a speed reference. In this
case, use P control mode to stop the motor.
2.6.5 Setting Speed Bias
The settling time for positioning can be reduced by assigning bias to the speed reference out-
put part in the Servopack. To assign bias, use the following constant.
Cn-1C
BIASLV
Bias
Unit:
min
1
Setting
Range: 0
to 450
Factory
Setting: 0
For Position Control
This parameter is set to assign an offset to a speed ref-
erence in the Servopack.
Use this constant to shorten settling time.
Set this parameter according to machine conditions.
2
Positions
Contact speed
reference
Error pulse