4.3 Servopack Ratings and Characteristics
4-19
SGDF Servopack A3CSA2CSA1CS
Performance
Speed Control Range
*2
1:5000
Speed
Rli
Load Regulation 0% to 100%:0.01% max. (at rated speed)
p
Regulation
*3
Voltage
Regulation
0%
Temperature
Regulation
25°C±25°C: ±0.1% max. (at rated speed)
Frequency Characteristics 250 Hz (at J
L
=J
M
)
Torque Control
(Repeatability)
±2.0%
Accel/Decel Time Setting 0to10s
Input Signal Speed
Reference
Rated Reference
Voltage
±6 VDC (forward motor rotation with positive
reference) at rated speed
Variable setting range: ±2to±10 VDC at rated
speed
Input Impedance
Approx. 30 k
Circuit Time
Constant
Approx. 47 µs
Torque
Reference
Rated Reference
Voltage
±3 VDC (forward motor rotation with positive
reference) at rated torque
Variable setting range: ±1to±10 VDC at rated
torque
Input Impedance
Approx. 30 k
Circuit Time
Constant
Approx. 47 µs
I/O Signals Position
O
Output Form Phase-A, -B, -C line driver
/
g
Output
Frequency
Dividing Ratio
(16 to N) /N N=2048
*4
Sequence Input (2 Inputs) Servo ON, P drive (or motor forward/reverse by
zero-clamp drive reference, or contact input
speed control), alarm reset, current limit (select
from parameters)
Sequence Output (2 Outputs) Current limit detection,TGON, speed
coincidence, external brake interlock, servo
alarm (servo alarms are fixed, other settings are
selected from parameters)
Protective Functions Overcurrent, overload, overspeed, reference
input read error, overrun prevention, CPU error,
encoder error
Indicators LED indicators
Red: Alarm, Green: Ready
Others Torque control, zero-clamp operation (position
loop stop), soft start/stop, speed coincidence,
brake interlock signal output, JOG run,
autotuning
*
1
Use within the ambient temperature range. When enclosed in a box, the internal tem-
peratures must not exceed the ambient temperature range.
*
2
The lowest speed of the speed control range is the speed at which the motor does not
stop under 100% load.
4