4.6Specifications and Dimensional Drawings of Peripheral Devices
4-51
Note 1) Use cable with 60 V min. withstand voltage for main circuits.
2) Consider allowable current reduction ratio if cables are bundled in PVC or metal ducts.
3) Use heat-resistant cable under high ambient or panel temperature where normal vinyl
cables rapidly deteriorate.
4.6.2 Motor Cables
The dimensions and appearance of the motor cables are shown below. Specify the cable type
when ordering.
SGMM-A
With Connector at Both Ends
Without Brake
Type L mm (feet)
JZSP-CFM00-01
1000
+100
0
(3.3
+0.33
0
)
JZSP-CFM00-03
3000
+100
0
(10
+0.33
0
)
JZSP-CFM00-05
5000
+100
0
(16.7
+0.33
0
)
Shrink Tube
L
Cable: AWG20 x 4 C
UL2517 KQVQV, DP8409359
Cap: 5559-04P-210
Socket: 5558T
Receptacle: 5557-04R-210
Socket: 5556T
Label
4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents