This section describes causes and remedies for problems which cause an alarm display
and for problems which result in no alarm display.
5.2.1 Troubleshooting Problems with Alarm Display
Refer to the following tables to identify causes of Servo Drive problems that cause an alarm
display at the Digital Operator (A.jj or CPFjj) and take the remedy described.
The display, A.99, does not indicate an alarm.
Contact your Yaskawa representative if the problem cannot be solved by the described pro-
cedures.
1. A.02
Display and Outputs
Digital Operator Display Alarm Name Alarm Output
A.02 Parameters breakdown Output transistor is OFF
(alarm state)
Status when Alarm Occurred
The letters A and B in the following diagram correspond to the letters in the table. The letters
in bold type indicate the main causes of the display.
At power ON
A
,
B
Cause Remedy
A Power turned OFF during parameter write.
Alarm occurred next power ON.
Replace Servopack.
B Circuit board (1PWB) defective Replace Servopack.
2. A.04
Display and Outputs
Digital Operator Display Alarm Name Alarm Output
A.04 Parameter setting error Output transistor is OFF
(alarm state)
5