2.2Setting Parameters According to Host Controller
— 2-31 —
Contact Input Speed Control Operation
Contact input speed control performs the following operation.
The following input signals are used to start and stop the motor.
→ Input IN1 CN1-1
Speed Selection 1 For Speed/Torque
Control
→ Input IN2 CN1-2
Speed Selection 2 For Speed/Torque
Control
Contact Signal Parameter
Cn-02 Cn-01
Selected Speed
Bit 2 Bit A Bit B
0 0
Stop
Stopped by internal
speed reference 0
1 0
Stopped by zero-clamp
0 0
0 1
Analog speed reference (V-
REF) input
1
1 1
With zero-clamp func-
tion
0 1 SPEED1 (Cn-1F)
1 1
−−−− −−−−
SPEED2 (Cn-20)
1 0 SPEED3 (Cn-21)
Preset values (0 or 1) and input signal status in the portions indicated by horizontal
bars (−) are optional.
Set the rotation directions for Cn-1F, Cn-20, and Cn-21 in bits 3, 4, and 5 of Cn-02
respectively.
Note For the speed/torque control type, control by external reference (voltage refer-
ence) is possible when the contact input speed control function is used by setting
bits A and B of parameter Cn-01.
2