EasyManua.ls Logo

YASKAWA Sigma Mini SGMM Series - Page 87

YASKAWA Sigma Mini SGMM Series
283 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPLICATIONS
2.4.2 Zero-clampcont.
2-42
Cn-01
Setting
Control Mode
Bit B Bit A
Control
Mode
Zero-clamp Speed Control
This speed control allows the
zero-clamp function to be set when
the motor stops.
D A speed reference is input from
V-REF.
D /P-CON is used to turn the
zero-clamp function ON or OFF.
Servopack
Speed reference
Zero-clamp
(CN1-12)
/P-CON
(CN1-1*)
0 1
/P-CON is open
(OFF)
Turns
zero-clamp
function OFF
Zero-clamp is performed when the
following two conditions are met:
/P-CON si
g
nal is closed.
/P-CON is
closed (ON)
Turns
zero-clamp
function ON
/P CON
signal
is
closed
.
Motor speed is below the value set
in Cn-0F (ZCLVL).
D Torque reference input T-REF
cannot be used.
Settings
Set the motor speed level at which zero-clamp is to be performed in the following parameter.
Cn-0F
ZCLVL Zero-clamp
Level
Unit:
min
1
Setting Range:
0 to Maximum
Speed
Factory
Setting:
10
For Speed/Torque
Control
If zero-clamp speed control is selected, set the motor speed level at which zero-clamp is to be
performed.
Conditions for Zero-clamp
Zero-clamp is performed when all the following conditions are met:
Zero-clamp speed control is selected.(Bits A and B of memory switch Cn-01 are set to 1
and 0, respectively.)
/P-CON is turned ON (0 V).
Motor speed drops below the preset value.
Speed
V-REF speed reference
Preset value for
zero-clamp
/P-CON input
Zero-clamp being
performed
Open (OFF)
Closed (ON)
Time
2