EasyManua.ls Logo

YASKAWA Sigma Mini SGMM Series - Page 90

YASKAWA Sigma Mini SGMM Series
283 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.4Setting Stop Mode
2-45
For brake ON timing during motor operation, use Cn-15 and Cn-16.
Setting the Holding Brake
Set the following parameters to adjust brake ON timing so that holding brake is applied when
the motor stops.
Cn-15
BRKSPD
Speed Level at which
Brake Signal Is Output
during Motor
Operation
Unit:
min
1
Setting
Range:
0to
Maximum
Speed
Factory
Setting:
100
For
Speed/Torque
Control and
Position
Control
Cn-16
BRKWAI
Output Timing of Brake
Signal during Motor
Operation
Unit:
10 ms
Setting
Range: 10
to 100
Factory
Setting:
50
For
Speed/Torque
Control and
Position
Control
Cn-15 and Cn-16 are used to set brake timing when
the servo is turned OFF by input signal /S-ON or alarm
occurrence during motor rotation.
Brakes for Servomotors are designed as holding
brakes. Therefore, brake ON timing when the motor
stops must be appropriate. Adjust the parameter set-
tings while observing machine operation.
Conditions for /BK Signal Output During Motor Operation
The circuit between CN1-8 and CN1-3 is opened in either of the following situations.
1 Motor speed drops below the value set in Cn-15 (BRKSPD) after servo OFF occurs.
2 The time set in Cn-16 (BRKWAI) has elapsed since servo OFF occurred.
2
Brake Timing when Motor is in Stopped Status
Power OFF
by /S-ON
input or alarm
occurrence
Servo ON
Servo OFF
Motor speed
(min
1
)
Stop by coasting
to a stop
BRKSPD
(Cn-15)
/BK output
Release
brake
Apply brake
BRKWAI
(Cn-16)
When this time elapses, BK signal is output,
regardless of motor speed.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents