EasyManua.ls Logo

YASKAWA VIPA System MICRO M13-CCF0000 - Page 112

YASKAWA VIPA System MICRO M13-CCF0000
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
n At interrupt function, the counter starts counting with the last recent counter value
after gate restart.
Counter 0 ... 2
SW gate Gate function Reaction counter 0 ... 2
Edge 0-1 Abort count process Restart with load value
Edge 0-1 Interrupt count process Continue
5.6.6.3 Comparator
In the CPU a comparison value may be stored. During the counting procedure the
counter value is compared with the comparative value. Depending on the result of the
comparison the output channel of the counter and the status bit of STS_CMP of
SFB 47
can be set. In addition, you can configure a hardware interrupt. A comparison value can
be specified via the parametrization respectively the job interface of SFB 47.
Function
VIPA System MICRO
Deployment I/O periphery
Counting > Counter - Additional functions
HB400 | CPU | M13-CCF0000 | en | 16-47 112

Table of Contents