2. Push the screwdriver backwards:
ð
The connector is unlocked and can be removed.
CAUTION!
V
ia wrong operation such as pressing, the screwdriver down-
ward the release lever may be damaged.
3. Plug connector:
The connector is plugged by plugging it directly into the release lever
.
2.6 Demounting
2.6.1 Demounting CPU
By means of a screwdriver there is the possibility to remove the connectors e.g. for
module exchange with a fix wiring. For this each connector has indentations for unlocking
at the top. Unlocking takes place by the following proceeding:
1. Power-of
f your system.
2. Remove connector:
Insert your screwdriver from above into one of the indentations.
3. Push the screwdriver backwards:
ð
The connector is unlocked and can be removed.
CAUTION!
V
ia wrong operation such as pressing, the screwdriver down-
ward the connector may be damaged!
4. In this way
, remove all plugged connectors on the CPU.