5.2 Address assignment
Sub module Input address Access Assignment
AI5/AO2 800 WORD Analog input channel 0 (X6)
802 WORD Analog input channel 1 (X6)
Sub module Input address Access Assignment
DI24/DO16 136 BYTE Digital input I+0.0 ... I+0.7 (X1)
137 BYTE Digital input I+1.0 ... I+1.7 (X5)
Sub module Input address Access Assignment
Counter 816 DINT Channel 0: Counter value / Frequency value
820 DINT Channel 1: Counter value / Frequency value
824 DINT Channel 2: Counter value / Frequency value
828 DINT Channel 3: Counter value / Frequency value
Sub module Output address Access Assignment
Counter 816 DWORD reserved
820 DWORD reserved
824 DWORD reserved
828 DWORD reserved
Sub module Output address Access Assignment
DI24/DO16 136 BYTE Digital output Q+0.0 ... Q+0.7 (X2)
137 BYTE Digital output Q+1.0 ... Q+1.3 (X6)
5.3 Analog input
5.3.1
Properties
n 2xUx12Bit (0 ... 10V) fixed.
n The analog channels of the module are not isolated to the electronic power supply
.
n The analog part has no status indication.
Temporarily not used analog inputs must be connected to the concerning
ground.
VIPA System MICRO
Deployment I/O periphery
Analog input > Properties
HB400 | CPU | M13-CCF0000 | en | 16-47 87