3. Switch on the power supply
.
ð
After a short boot time the interface X2 MPI(PB) is ready for MPI communica-
tion with the MPI address 2.
To switch the interface X2 MPI(PB) to PROFIBUS functionality
you have to activate the according bus functionality by means
of a VSC storage media from VIP
A. By plugging the VSC
storage card and then an overall reset the according function-
ality is activated.
Ä
Chapter 4.15 ‘Deployment storage media -
VSD, VSC’ on page 79
1 RS485 interface
2 Periphery
Never connect the cable shield and the M5V (pin 5) together, since the
interfaces could be destroyed!
X2 MPI(PB)
DE
Description
green
n Slave is in DE (data exchange).
n Slave exchanges data with the master
.
n Slave is in RUN state
green blinking
n Slave CPU is in state start-up.
n Slave-CPU is without master
.
n There is no power supply
.
n Slave has no configuration.
Status indication
VIPA System MICRO
Option: Deployment PROFIBUS communication
PROFIBUS communication via extension module EM M09
HB400 | CPU | M13-CCF0000 | en | 16-47 171