You get valid IP address parameters from your system administrator. The assignment of
the IP address data happens online in the Siemens TIA Portal with the following pro-
ceeding:
1. Start the Siemens TIA Portal.
2. Switch to the ‘Project view’ .
3. Click in the ‘Project tree’ at ‘Online access’ and choose here by a doubleclick your
network card, which is connected to the Ethernet PG/OP channel.
4. T
o get the stations and their MAC address, use the ‘Accessible device’ . This can
be found at the front of the CPU labelled as "MAC PG/OP: ...".
5. Choose from the list the module with the known MAC address (Onboard PG/OP
[MAC address]) and open with "Online & Diagnostics" the diagnostics dialog in the
Project area.
6. Navigate to Functions > Assign IP address. T
ype in the IP configuration like IP
address, subnet mask and gateway.
7. Confirm with [Assign IP configuration].
ð
Directly after the assignment the Ethernet PG/OP channel is online reachable
using the set IP address data. The value remains as long as it is reassigned, it
is overwritten by a hardware configuration or an factory reset is executed.
Due to the system you may get a message that the IP address could not
be assigned. This message can be ignored.
1. Open your project.
2. If not already done, configure in the ‘Device configuration’
a Siemens CPU 314C-2
PN/DP (314-6EH04-0AB0 V3.3).
3. As Ethernet PG/OP channel place at slot 4 the Siemens CP 343-1 (6GK7
343-1EX30 0XE0 V3.0).
4. Open the "Property" dialog by clicking on the CP 343-1EX30 and enter for the CP at
"Properties" at "Ethernet address" the IP address data, which you have assigned
before.
5. T
ransfer your project.
Assign IP address param-
eters
Take IP address parame-
ters in project
VIPA System MICRO
Configuration with TIA Portal
TIA Portal - Hardware configuration - Ethernet PG/OP channel
HB400 | CPU | M13-CCF0000 | en | 16-47 206