EasyManua.ls Logo

YASKAWA VIPA System MICRO M13-CCF0000 - Page 217

YASKAWA VIPA System MICRO M13-CCF0000
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Event ID Description
0x64: VSFC
0x66: VSFB
ZInfo3 : BstNr
0xE300 Internal flash writing finished (Copy Ram2Rom)
0xE310 Internal flash writing finished (reload after battery failure)
0xE400 FSC card was plugged
DatID : FeatureSet Trialtime in minutes
ZInfo1 : Memory extension in kB
ZInfo2 : FeatureSet PROFIBUS
ZInfo2 : FeatureSet field bus
ZInfo2 : FeatureSet motion
ZInfo2 : Reserved
0xE401 FSC card was removed
DatID : FeatureSet Trialtime in minutes
ZInfo1 : Memory extension in kB
ZInfo2 : FeatureSet PROFIBUS
ZInfo2 : FeatureSet field bus
ZInfo2 : FeatureSet motion
ZInfo2 : Reserved
ZInfo3 : Source of the FSC
0: CPU
1: Card
0xE402 A configured functionality is not activated
ZInfo1 : FCS ErrorCode
1: The PROFIBUS functionality is disabled The interface acts further as MPI interface
2: The EtherCAT functionality is not enabled
3: The number of configured axis is not enabled
0xE403 FSC can not be activated in this CPU
ZInfo1 : Memory extension in kB
ZInfo2 : FeatureSet PROFIBUS
ZInfo2 : FeatureSet field bus
ZInfo2 : FeatureSet motion
ZInfo2 : Reserved
0xE404 FeatureSet deleted due to CRC error
DatID : Not relevant to the user
0xE405 The trial time of a feature set or MMC has expired
DatID : Not relevant to the user
0xE410 A CPU feature set was activated
VIPA System MICRO
System specific event IDs
HB400 | CPU | M13-CCF0000 | en | 16-47 217