Page – 106/155 AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
Error code Effect Condition
Restart
procedure
MDI /
LED
CODE
CAN
OPEN
CODE
ZAPI
CODE
WAIT MOT.P STILL
Valve, pump, traction stopped,
LC opened, EB applied
Start-up
45 FFBA 186
HANDBRAKE
Traction/Pump motor is stopped
Start-up, stand-by,
running
Traction/Pump
request
46 FFDD 221
MOT.PHASE SH.
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up
Traction/Pump
request
47 FFC4 196
THROTTLE PROG.
MC remains closed, EB is
applied (the command is
released), Traction stopped
Start-up, Stand-by,
running
Valves or
Traction/Pump
Request
48 FFF3 243
LIFT+LOWER
Pump is stopped
Start-up, stand-by,
running
Pump request 49 FFBB 187
PUMP VACC NOT OK
Traction/Pump motor is stopped
Start-up, stand-by,
running
Lift/lower
potentiometer at
rest
50 FFBC 188
TILLER OPEN LC opens
Start-up, stand-by,
running
Valves or
Traction/Pump
Request
51 0000 228
PUMP I=0 EVER
MC is open, EB is applied (the
command is released), DC pump
stopped
Running Pump request 52
2312
52
STBY I HIGH
MC is not closed, EB is applied,
Traction/Pump stopped
Start-up, stand-by
Valves or
Traction/Pump
request
53 2311 53
PUMP I NO ZERO
MC is open, EB is applied (the
command is released), DC pump
stopped
Running Pump request 56 FFBF 191
OVERLOAD
MC is not closed, EB is applied,
Traction/Pump stopped
Running
Valves or
Traction/Pump
request
57 FFB4 180
WRONG ZERO
MC is opened, EB is applied,
Traction/Pump, valves stopped
Start-up
Valves or
Traction/Pump
request
58 3201 252
CAPACITOR CHARGE
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up
Valves or
Traction/Pump
request
60 3130 60
THERMIC SENS. KO
Maximum current is reduced
according to parameter MOT.T.
T.CUTBACK and speed is
reduced to a fixed value.
Start-up, stand-by,
running
61 4211 250
TH. PROTECTION
Traction controller reduces the
max current linearly from Imax
(85°C) down to 0 A (105°C)
Start-up, stand-by,
running
62 4210 62
BRAKE RUN OUT Traction is stopped
Start-up, stand-by,
running
Traction/Pump
Request
63 FFCC 204
TILLER ERROR Traction stopped, EB applied Stand-by, running
H&S input
released
64 FFB9 185
MOTOR TEMPERAT.
Maximum current is linearly
reduced (see paragraph 9.14)
and speed is reduced to a fixed
value.
Start-up, stand-by,
running
65 4110 65
MOTOR TEMP. STOP
EB is applied, Traction/Pump,
valves stopped
Start-up, stand-by,
running
65 FFB2 178
NO CAN MSG.
MC is opened, EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
67 8130 248
SENS MOT TEMP KO
Maximum current is reduced
according to parameter MOT.T.
T.CUTBACK and speed is
reduced to a fixed value.
Start-up, stand-by,
running
68 4311 218
SMARTDRIVER KO
MC is not closed,
Traction/Pump, valves stopped
Start-up Traction request 69 3302 193
EPS RELAY OPEN
Traction/Pump motor is stopped
Start-up, stand-by,
Running
Valves or
Traction/Pump
request
70 FFCD 205
WRONG RAM MEM.
MC is opened, EB is applied,
Traction/Pump, valves stopped
Stand-by Key re-cycle 71 FFD2 210
DRIVER SHORTED
MC is opened (the command is
released), EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
74 3211 74