Page – 54/155 AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
PARAMETER CHANGE
Parameter Allowable range Description
TILLER BRAKING
(T, TM)
0.1 s ÷ 25.5 s
(steps of 0.1 s)
This parameter defines the deceleration ramp performed
after the tiller/seat switch is released, i.e. the time needed
to decelerate the motor from 100 Hz down to 0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 9.5).
INVERS. BRAKING
(T, TM, CO)
0.1 s ÷ 25.5 s
(steps of 0.1 s)
This parameter defines the deceleration ramp performed
when the direction switch is toggled during drive, i.e. the
time needed to decelerate the motor from 100 Hz down to
0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 9.5).
DECEL. BRAKING
(T, TM, P, CO)
0.1 s ÷ 25.5 s
(steps of 0.1 s)
This parameter defines the deceleration ramp performed
when the accelerator is released but not completely, i.e.
the time needed to decelerate the motor from 100 Hz down
to 0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 9.5).
PEDAL BRAKING
(T, TM, CO)
0.1 s ÷ 25.5 s
(steps of 0.1 s)
This parameter defines the deceleration ramp performed
when the braking pedal is pressed, i.e. the time needed to
decelerate the motor from 100 Hz down to 0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 9.5).
SPEED LIMIT BRK.
(T, TM)
0.1 s ÷ 25.5 s
(steps of 0.1 s)
This parameter defines the deceleration ramp performed
upon a speed-reduction request, i.e. the time needed to
decelerate the motor from 100 Hz down to 0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 9.5).
STEER BRAKING
(T, TM)
0.1 s ÷ 25.5 s
(steps of 0.1 s)
This parameter defines the deceleration ramp related to
the steering angle, i.e. the time needed to decelerate the
motor from 100 Hz down to 0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 9.7).
MAX SPEED FORW
(T, TM)
0% ÷ 100%
(steps of 1%)
This parameter defines the maximum speed in forward
direction as a percentage of TOP MAX SPEED.
MAX SPEED BACK
(T, TM)
0% ÷ 100%
(steps of 1%)
This parameter defines the maximum speed in backward
direction as a percentage of TOP MAX SPEED.
MAX SPEED LIFT
(P)
0% ÷ 100%
(steps of 1%)
This parameter defines the maximum speed of the pump
motor during lift, as a percentage of the maximum voltage
applied to the pump motor.
1ST PUMP SPEED
(P)
0% ÷ 100%
(steps of 1%)
This parameter defines the speed of the pump motor when
1
st
speed is requested. It represents a percentage of the
maximum pump speed.
2ND PUMP SPEED
(P)
0% ÷ 100%
(steps of 1%)
This parameter defines the speed of the pump motor when
2
nd
speed is requested. It represents a percentage of the
maximum pump speed.