DESCRIPTION
Carl Zeiss Compact version with stand C Stemi DV4 / DR
2-4 B 40-003 e 08/00
2.2.4 Technical Data
Dimensions (width x depth x height)
Stemi DV4 / DR......................................................................................... 230 mm x 300 mm x 350 mm
Weight
Stemi DV4 (microscope body)........................................................................................................1.5 kg
Stemi DV4 SPOT (microscope body) ...............................................................................................1.5 kg
Stemi DR 1040 (microscope body)..................................................................................................1.5 kg
Stemi DR 1663 (microscope body)..................................................................................................1.5 kg
Stand C.........................................................................................................................................3.5 kg
Ambient conditions
Storage and transport (in packaging):
Permissible ambient temperature...................................................................................... -10 to +60 °C
Permissible relative humidity ............................................................................ 20 % to 85 % at +35 °C
Atmospheric pressure............................................................................................ 800 hPa to 1060 hPa
Operation
Permissible ambient temperature..................................................................................... +10 to +40 °C
Permissible relative humidity ............................................................................................ maximal 85 %
Atmospheric pressure............................................................................................ 800 hPa to 1060 hPa
Pollution degree................................................................................................................................... 2
Operating data
Protection class..................................................................................................................................... II
Protection type............................................................................................................................... IP 30
Electrical safety................................................................ in compliance with DIN EN 61010 (IEC 1010-1)
including CSA, UL, ENEC, Q and MITI regulations
Excess voltage category ........................................................................................................................ II
Radio interference suppression...................................................... in accordance with EN 55011, Class B
Insensitivity to noise................................................................................ in accordance with EN 50082-2
Line voltage............................................................................................................ 100 to 240 V ±10 %
Change of line voltage is not required!
Line frequency..................................................................................................................... 50 to 60 Hz
Power consumption...................................................................................................................... 30 VA