175
ADJUSTMENT
F_02_129 F_02_130 F_02_131
CALIBRATION OF THE TRAVELLING SPEED OF THE DIGITAL DASHBOARD
After the assembly in the production
plant the dashboard is calibrated.
Perform repeated calibration:
− In case of a considerable wear of the
tyres
− When installing new tyres
− When replacing the dashboard.
CALIBRATION SEQUENCE
− In a suitable area mark a 100m long
track.
− Inflate the tractor tyres to the prescribed
pressure, see the tables of this Man-
ual.
− Start the engine.
− Drive the tractor to the beginning of the
100m track.
− Simultaneously press the button (A)
and button (B). Hold the buttons de-
pressed for 7 s. The dashboard is
switched over to the calibration mode.
“Start” will start flashing on the dis-
play.
− Press the button (B). “Stop” will start
flashing on the display.
− Drive the tractor at a steady speed of
approx. 10 km/h.
− The display will show the number of im-
pulses detected by the travelling sen-
sor.
− After covering the whole distance of
100 m stop the tractor at the marked
end of the track (see fig. F_02_129).
− Press the button (B). This way you will
save the number of impulses detected
by the travelling sensor in the memory.
The dashboard is calibrated and ready
for operation.