Item Description
Door Lock Delay
(s)
The length of time that the device controls the electric lock to be unlocked. Valid
value: 1~10 seconds (0 second represents disabling the function).
Door Sensor
Delay (s)
If the door is not closed and locked after opening for a certain duration (Door Sensor
Delay), an alarm will be triggered. The valid value of Door Sensor Delay ranges from 1 to
255 seconds.
Door Sensor
Type
There are three types of Door Sensor: None, Normal Open, and Normal Closed.
None means door sensor is not in use; Normal Open means the door is always opened
when powered; and Normal Closed means the door is always closed when powered.
Door Alarm
Delay (s)
When the state of the door sensor is inconsistent with that of the door sensor type,
alarm will be triggered after a certain time. This time is the Door Alarm Delay (the
value ranges from 1 to 999 seconds).
Speaker Alarm
To transmit a sound alarm or disassembly alarm from the local. When the door is
closed, or the verification is successful, the system cancels the alarm from the local.