Module Minimum consumption [W] Maximum consumption [W]
Main unit with camera 2.36 11.57
RFID card reader 13.56 MHz 0.44 0.82
I/O 0.31 0.65
5-button 0.19 1.16
Touch display 1.16 2.02
I/O 0.31 0.65
Tamper switch 0.31 0.65
OSDP
Wiegand 0.46 0.46
Bluetooth reader 0.20 0.67
Total 5.74 18.65
It is obvious from the specimen configuration that all the modules have sufficient outputs when
an external power supply is used. When a PoE supply is used, the power output is insufficient for
all the modules, which results in automatic decrease in backlight level, active output current
supply, volume and LED intensity. Some modules need a specific power output for their specific
activities: the I/O module, e.g., requires0.13 W for relay closing (not calculated for minimum
consumption).
Infopanel
The Infopanel (Part No.9155030)is one of the2N
®
IP Versointercom elements and is used for
inserting and backlighting printed information.
The module contains two2N
®
IP Versobus connectors.
These two connectors are fully interchangeable and can be used both as inputs from the
main unit and outputs to other modules.
If this module is the last one on the bus, one of the connectors remains unconnected.
The module package includes a 220 mm long interconnecting cable.
Nametag dimensions: 69.2 (W) x 86.7 (H) mm (dimensional tolerance: +0; 0.5 mm).