via this two-wire cable and so can be added to an existing installation. Thanksto its compact
dimensions, the device can be installed into a standard mounting box.
Connection:
Connect the2N
®
Security Relayto the intercom as follows:
To the intercom active output (OUT1)
Connect the electric lock to the2N
®
Security Relayoutput as follows:
To the switched output.
To the passive output in series with the external power supply.
The device also supports a Departure button connected between the ‘PB’ and ‘- Helios IP /
intercom’terminals. Press the Departure button to activate the output for 5 seconds.
Status signalling:
Green LED Red LED Status
flashing off Operational mode
on off Activated output
flashing flashing Programming mode – waiting for
initialisation
on flashing Error – wrong code received