The module provides logical inputs and outputs for
sensor integration. The module is installed under
another module, i.e. needs no separate position.
Inputs and outputs
RELAY1 – RELAY1 terminals with accessible 30 V /
1 A AC/DC NO/NC contact
RELAY2 – RELAY2 terminals with accessible 30 V /
1 A AC/DC NO/NC contact
IN1 – IN1 terminals for input in passive/ active
mode(−30 V to +30 V DC)
 OFF = open OR U
IN
> 1.5 V
 ON = closed contact OR U
IN
< 1.5 V
IN2 – IN2 terminals for input in passive/active
mode(−30 V to +30 V DC)
 OFF = open OR U
IN
> 1.5 V
 ON = closed contact OR U
IN
< 1.5 V
TAMPER – Tamper switch (9155038) input