9-4
Configuration
System clock displayed by the
display clock command
Example
If the original system clock is in the
daylight saving time range, the
original system clock +
summer-offset is displayed.
Configure: clock summer-time ss one-off
00:30 2005/1/1 1:00 2005/8/8 2
Display: 03:00:00 ss Sat 01/01/2005
If date-time is not in the daylight
saving time range, date-time is
displayed.
Configure: clock datetime 1:00 2007/1/1
and clock summer-time ss one-off 1:00
2006/1/1 1:00 2006/8/8 2
Display: 01:00:00 UTC Mon 01/01/2007
1 and 3
If date-time is in the daylight saving
time range, “date-time” +
summer-offsetis displayed.
Configure: clock datetime 8:00 2007/1/1
and clock summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2
Display: 10:00:00 ss Mon 01/01/2007
If date-time is not in the daylight
saving time range, date-time is
displayed.
Configure: clock summer-time ss one-off
1:00 2007/1/1 1:00 2007/8/8 2 and clock
datetime 1:00 2008/1/1
Display: 01:00:00 UTC Tue 01/01/2008
Configure: clock summer-time ss one-off
1:00 2007/1/1 1:00 2007/8/8 2 and clock
datetime 1:30 2007/1/1
Display: 23:30:00 UTC Sun 12/31/2006
[1], 3 and 1
date-time is in the daylight saving
time range:
If the value of “date-time” -
“summer-offset” is not in the
summer-time range, “date-time” -
“summer-offset” is displayed;
If the value of “date-time” -
“summer-offset” is in the
summer-time range, date-time is
displayed.
Configure: clock summer-time ss one-off
1:00 2007/1/1 1:00 2007/8/8 2 and clock
datetime 3:00 2007/1/1
Display: 03:00:00 ss Mon 01/01/2007
Configure: clock timezone zone-time add
1 and clock summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2
Display: 02:00:00 zone-time Sat
01/01/2005
If the value of the original system
clock ± “zone-offset” is not in the
summer-time range, the original
system clock ± “zone-offset” is
displayed.
Configure: clock timezone zone-time add
1 and clock summer-time ss one-off 1:00
2005/1/1 1:00 2005/8/8 2
Display: 04:00:00 ss Sat 01/01/2005
2 and 3 or 3
and 2
If the value of the original system
clock ± “zone-offset” is in the
summer-time range, the original
system clock ± “zone-offset”
+ ”summer-offset” is displayed.
Configure: clock datetime 1:00 2007/1/1,
clock timezone zone-time add 1 and
clock summer-time ss one-off 1:00
2008/1/1 1:00 2008/8/8 2
Display: 02:00:00 zone-time Mon
01/01/2007
If the value of
"date-time"±"zone-offset" is not in
the summer-time range,
"date-time"±"zone-offset" is
displayed.
Configure: clock datetime 1:00 2007/1/1,
clock timezone zone-time add 1 and
clock summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2
Display: 04:00:00 ss Mon 01/01/2007
1, 2 and 3 or 1, 3
and 2
If the value of
"date-time"±"zone-offset" is in the
summer-time range,
"date-time"±"zone-offset"+”summer-
offset” is displayed.
Configure: clock timezone zone-time add
1, clock summer-time ss one-off 1:00
2008/1/1 1:00 2008/8/8 2 and clock
datetime 1:00 2007/1/1
Display: 01:00:00 zone-time Mon
01/01/2007