78-9000-5020-0 Rev C 11
Active Frequencies:
7550 577 Hz, 1 kHz, 8 kHz, 33 kHz, 82 kHz, 200 kHz
7550E (International) 577 Hz, 1 kHz, 8 kHz, 33 kHz, 82 kHz, 133 kHz
ALL indicates that the following active frequencies are transmitting simultaneously:
7550 577 Hz, 8 kHz, 33 kHz, 200 kHz
7550E (International) 577 Hz, 8 kHz, 33 kHz, 133 kHz
[T-4] Digital Display:
Indicator Flags: These ags coincide with the operational mode of the transmitter.
Starting from bottom left to upper right; Ohm-meter [T-2], Voltage (at start up the
transmitter checks for foreign voltage), Output Level (no ag = normal output;
ag = high output; ashing ag = maximum output) and Trace mode [T-3].
Digital Display: Indicates frequency, relative current, resistance, battery level and
voltage (if present on target).
[T-5] Output Level: Cycles output power level.
Normal=No Flag; High=Flag; Maximum=Flashing Flag (indicated in Digital Display [T-4])
NOTE: An external 12-volt power source is required to obtain Maximum Output level.
[T-6] Output Jack: Port for direct connect cables or Dyna-coupler cable.
[T-7] External Jack: Port to connect cigarette lighter adapter cable, or rechargeable
battery (2200RB). Input voltage level: 9-18 VDC.
G. 3M
Dynatel
Locator 7573 Transmitter Keypad and Connector Definitions
off
+
-
o
Trace
on
on
Output Level
Dynatel
TM
7573
T-1 T-2 T-3 T-4 T-5 T-6 T-7
[T-1] off: Turns unit off and performs battery test.
[T-2] on: Ohm-meter/Fault Locate/Tone: Turns the unit on and cycles through the
following commands when pressed repeatedly.
Ohm-meter: Measures the continuity of the trace conductor/pipe and its far-end
ground. It is also used to measure the fault resistance to earth.
Fault Locate: In this mode, the transmitter sends two alternating locating frequencies
(577 Hz and 33 kHz) as well as fault signals 10 and 20 Hz.
Tone: In the tone mode, the transmitter generates two frequencies simultaneously:
7573 577 Hz and 200 kHz signals.
7573E (International) 577 Hz and 133 kHz signals.
[T-3] on: Trace (frequency): Turns the unit on and places the unit in Trace mode.
Select Frequency: Press Trace [T-3] repeatedly to cycle through the transmitter's
active frequencies. The selected frequency will be displayed [T-4].

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3M Dynatel 7550 Series and is the answer not in the manual?

3M Dynatel 7550 Series Specifications

General IconGeneral
Brand3M
ModelDynatel 7550 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals