Operation Manual / 4 Product description / A100-M axial
2 Removal and installation / 2.3 Installing the turbocharger
© Copyright 2019 ABB. All rights reserved. HZTL4033_DE Revision C February 2019
Fixing clamping nuts
Fig.13: CE foot contact surface
u Tighten clamping nuts on compressor end (CE) (see Tightening the clamping nut 16).
Fig.14: TE foot: Handling of cup spring contact surface / foot contact surface
u Coat the contact surface (F) for the cup springs (X) (see Table3: Foot bolt dimensions
14) at the foot of the turbine end (TE) with high-temperature grease.
u Tighten clamping nuts on turbine end (TE) (see Tightening the clamping nut 16).