EasyManuals Logo

ABB A170-M Series Original Operation Manual

ABB A170-M Series
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
Operation Manual / 4 Product description / A100-M axial
6 Periodic maintenance / 6.4 Cleaning the compressor during opera-
tion
© Copyright 2019 ABB. All rights reserved. HZTL4033_DE Revision C February 2019
6.4.5 Wet cleaning with external water pressure vessel
Operating state prerequisites for cleaning the compressor
On V-engines with several turbochargers per engine, parallel cleaning of both turbochargers
is recommended. This cleaning process is faster and reduces the risk of surging of the tur-
bocharger.
To carry out the cleaning operation checked and recommended by ABB Turbo Systems, the
following prerequisites must be fulfilled:
¡ Engine load 50 ... 85%
u Start the cleaning operation according to the following description.
Operation of compressor wet cleaning
Fig.23: Operation of water pressure vessel
Operation of the water pressure vessel
u The prerequisites for operating state for cleaning the compressor with XC3 must be ful-
filled before the cleaning.
u Screw out sealing plug (X).
u Fill container with pure water.
u Screw in sealing plug (X).
u Push valve activator (Y) against the spring and hold for 10 to 15 seconds until the whole
volume of water is injected.
Page 42 / 108

Table of Contents

Other manuals for ABB A170-M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB A170-M Series and is the answer not in the manual?

ABB A170-M Series Specifications

General IconGeneral
BrandABB
ModelA170-M Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals