EasyManua.ls Logo

ABB A170-M Series - Page 69

ABB A170-M Series
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / 4 Product description / A100-M axial
6 Periodic maintenance / 6.4 Cleaning the compressor during opera-
tion
© Copyright 2019 ABB. All rights reserved. HZTL4033_DE Revision C February 2019
6.4.3 Principle of wet cleaning
Principle of wet cleaning
To clean the compressor stage during operation, water is injected before the compressor
wheel.
The water does not act as a solvent. The coating is removed by the mechanical action of the
impacting droplets. The process is particularly suitable as long as the contamination is not
too advanced.
CAUTION
Corrosion and deposits when cleaning
Salt water and cooling water treatment substances damage and adversely
affect turbocharger parts.
u Never use salt water, but only pure water for cleaning.
CAUTION
Volume of water
Uncontrolled volumes of water can damage the turbocharger and the en-
gine.
u Never connect the water line without the orifice specified for the tur-
bocharger.
Page 39 / 108

Table of Contents

Other manuals for ABB A170-M Series

Related product manuals