ACQ550-U1 User’s Manual 297
Technical data
The following table lists the standard stress testing that the ACQ550 passes.
Materials
Contamination
levels
(IEC 721-3-3)
No conductive dust allowed.
The ACQ550 should be installed in
clean air according to enclosure
classification.
Cooling air must be clean, free from
corrosive materials and free from
electrically conductive dust.
Chemical gases: Class 3C2
Solid particles: Class 3S2
Storage
No conductive dust allowed.
Chemical gases: Class 1C2
Solid particles: Class 1S2
Transportation
No conductive dust allowed.
Chemical gases: Class 2C2
Solid particles: Class 2S2
Stress tests
Without shipping package Inside shipping package
Sinusoidal
vibration
Mechanical conditions: In accordance
with IEC 60721-3-3, Class 3M4
2…9 Hz 3.0 mm (0.12 in)
9…200 Hz 10 m/s
2
(33 ft/s
2
)
In accordance with ISTA 1A and 1B
specifications.
Shock
Not allowed In accordance with IEC 68-2-29:
max. 100 m/s
2
(330 ft/s
2
), 11ms
Free fall
Not allowed 76 cm (30 in), frame size R1
61cm (24 in), frame size R2
46 cm (18 in), frame size R3
31 cm (12 in), frame size R4
25 cm (10 in), frame size R5
15 cm (6 in), frame size R6
Material specifications
Drive enclosure
PC/ABS 2.5 mm, color NCS 1502-Y or NCS 7000-N
Hot-dip zinc coated steel sheet 1.5…2 mm, thickness of coating 20
micrometers. If the surface is painted, the total thickness of the coating (zinc
and paint) is 80…100 micrometers.
Cast aluminium AlSi
Extruded aluminium AlSi
Package
Corrugated board, expanded polystyrene, plywood, raw wood (heat dried).
Package wrap consists of one or more of the following: PE-LD plastic wrap, PP
or steel bands.
Ambient environment requirements
Installation site
Storage and transportation in the
protective package

Table of Contents