72 ACQ550-U1 User’s Manual
Parameters
1205 CONST SPEED 4 0.0…500.0 Hz / 0…30000 rpm 0.1 Hz / 1 rpm -U1: 24.0 Hz / 1440 rpm
1206
CONST SPEED 5 0.0…500.0 Hz / 0…30000 rpm 0.1 Hz / 1 rpm -U1: 30.0 Hz / 1800 rpm
1207 CONST SPEED 6 0.0…500.0 Hz / 0…30000 rpm 0.1 Hz / 1 rpm -U1: 48.0 Hz / 2880 rpm
1208
CONST SPEED 7 0.0…500.0 Hz / 0…30000 rpm 0.1 Hz / 1 rpm -U1: 60.0 Hz / 3600 rpm
1209
TIMED MODE SEL 1=EXT/CS1/2/3, 2 = CS1/2/3/4 1 2 (CS1/2/3/4)
Group 13: ANALOG INPUTS
1301
MINIMUM AI1 0.0…100.0% 0.1% 0.0%
1302 MAXIMUM AI1 0.0…100.0% 0.1% 100.0%
1303
FILTER AI1 0.0…10.0 s 0.1 s 0.1 s
1304
MINIMUM AI2 0.0…100.0% 0.1% 20.0%
1305 MAXIMUM AI2 0.0…100.0% 0.1% 100.0%
1306
FILTER AI2 0.0…10.0 s 0.1 s 0.1 s
Group 14: RELAY OUTPUTS
1401
RELAY OUTPUT 1 0…44, 46, 47, 52 1 1 (READY)
1402
RELAY OUTPUT 2 0…44, 46, 47, 52 1 2 (RUN)
1403
RELAY OUTPUT 3 0…44, 46, 47, 52 1 3 [FAULT(-1)]
1404 RO 1 ON DELAY 0.0…3600.0 s 0.1 s 0.0 s
1405
RO 1 OFF DELAY 0.0…3600.0 s 0.1 s 0.0 s
1406
RO 2 ON DELAY 0.0…3600.0 s 0.1 s 0.0 s
1407 RO 2 OFF DELAY 0.0…3600.0 s 0.1 s 0.0 s
1408
RO 3 ON DELAY 0.0…3600.0 s 0.1 s 0.0 s
1409
RO 3 OFF DELAY 0.0…3600.0 s 0.1 s 0.0 s
1410 RELAY OUTPUT 4 0…44, 46, 47, 52 1 0 (NOT SEL)
1411
RELAY OUTPUT 5 0…44, 46, 47, 52 1 0 (NOT SEL)
1412
RELAY OUTPUT 6 0…44, 46, 47, 52 1 0 (NOT SEL)
1413 RO 4 ON DELAY 0.0…3600.0 s 0.1 s 0.0 s
1414
RO 4 OFF DELAY 0.0…3600.0 s 0.1 s 0.0 s
1415
RO 5 ON DELAY 0.0…3600.0 s 0.1 s 0.0 s
1416 RO 5 OFF DELAY 0.0…3600.0 s 0.1 s 0.0 s
1417
RO 6 ON DELAY 0.0…3600.0 s 0.1 s 0.0 s
1418
RO 6 OFF DELAY 0.0…3600.0 s 0.1 s 0.0 s
Group 15: ANALOG OUTPUTS
1501
AO1 CONTENT SEL 99…178 1 102 (parameter 0102
OUTPUT SPEED)
1502
AO1 CONTENT MIN - - Depends on the signal
selected with par. 1501
1503
AO1 CONTENT MAX - - Depends on the signal
selected with par. 1501
1504
MINIMUM AO1 0.020.0mA 0.1mA 0.0mA
1505
MAXIMUM AO1 0.0…20.0 mA 0.1 mA 20.0 mA
1506
FILTER AO1 0.010.0s 0.1s 0.1s
1507
AO2 CONTENT SEL 99…178 1 104 (parameter 0104
CURRENT)
1508
AO2 CONTENT MIN - - Depends on the signal
selected with par. 1507
1509
AO2 CONTENT MAX - - Depends on the signal
selected with par. 1507
Code Name Range Resolution Default User S

Table of Contents